- Member biogears::AnesthesiaMachine::CalculateEquipmentLeak ()
- Error: Invalid Airway Mode Encountered in Compute Equipment Leak function
- Member biogears::Cardiovascular::CalculateVitalSigns ()
Fatal: Diastolic pressure has fallen below -2
Fatal: Systolic pressure has exceeded 700
- Member biogears::Cardiovascular::ChronicAnemia ()
- if too much hemoglobin is removed, we will no longer meet validation, so set to maximum amount that can be removed.
- Member biogears::Cardiovascular::ChronicPericardialEffusion ()
Cannot specify volume accumulation greater than 1000 mL. Accumulated volume is now set at 1000 mL.
Cannot specify volume accumulation less than 0 mL. Accumulated volume is now set at 0 mL.
- Member biogears::Cardiovascular::ChronicRenalStenosis ()
Cannot specify left occlusion fraction less than zero
Cannot specify right occlusion fraction less than zero
Cannot specify left occlusion fraction greater than one
Cannot specify right occlusion fraction greater than one
- Member biogears::Cardiovascular::CPR ()
- Warning: CPR compression ratio must be a positive value between 0 and 1 inclusive.
- Member biogears::Cardiovascular::PericardialEffusion ()
Effusion rate is out of physiologic bounds. Effusion rate is reset to 1.0 milliliters per second.
Cannot specify effusion rate less than zero. Effusion rate is now set to 0.0.
- Member biogears::Drugs::AdministerSubstanceBolus ()
- Error: Unavailable Administration Route
- Member biogears::Drugs::CalculatePartitionCoefficients ()
- Fatal: Binding Protein not supported
- Member biogears::Drugs::Load (const CDM::BioGearsDrugSystemData &in)
- Error: Unable to find substance for IV bolus administration
- Member biogears::Environment::ProcessActions ()
Warning: SurfaceArea and SurfaceAreaFraction are both set. The largest fraction will be used.
Warning: Neither SurfaceArea nor SurfaceAreaFraction are set. A fraction of 1 will be used.
Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.
Warning: SurfaceArea and SurfaceAreaFraction are both set. The largest fraction will be used.
Warning: Neither SurfaceArea nor SurfaceAreaFraction are set. A fraction of 1 will be used.
Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.
Warning: AppliedSurfaceArea and AppliedSurfaceAreaFraction are both set. The largest fraction will be used.
Warning: Neither AppliedSurfaceArea nor AppliedSurfaceAreaFraction are set. A fraction of 1 will be used.
Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.
- Member biogears::Environment::StateChange () override
- Fatal: Total ambient/environment gas volume fractions must sum to 1.0.
- Member biogears::ErrorHandler::handleError (const xercesc::DOMError &err)
- Invalid schema file
- Member biogears::Gastrointestinal::PreProcess () override
- Unable to read consume meal action file
- Member biogears::Inhaler::Administer ()
: Already processing a Substance Inhalation, ignoring this command.
Fatal: Inhaled substance does not have a density value.
- Member biogears::Renal::CalculateActiveTransport ()
- Fatal: Unrecognized renal clearance type
- Member biogears::Respiratory::ImpairedAlveolarExchange ()
Fatal: The Impaired Alveolar Exchange action must include either a surface area of fraction.
Error: The Impaired Alveolar Exchange action cannot have both an impaired surface area and impaired fraction defined. Defaulting to the surface area value.
- Member biogears::Respiratory::Pneumothorax ()
Patient: Cannot perform an intervention if Tension Pneumothorax is not present on that side.
Patient: Cannot perform an intervention if Tension Pneumothorax is not present on that side.
Patient: can't process needle decompression if no pneumothorax is present
Patient: can't process a chest occlusive dressing if no pneumothorax is present
- Member biogears::SEActionManager::ProcessAction (const SEAction &action)
- Unsupported Action
- Member biogears::SEAnesthesiaMachineActionCollection::ProcessAction (const CDM::AnesthesiaMachineActionData &action)
- Unsupported Action
- Member biogears::SEConditionManager::ProcessCondition (const CDM::ConditionData &condition)
- Unsupported Condition
- Member biogears::SEEnvironment::ProcessChange (const SEInitialEnvironment &change)
- Unable to read Configuration Action file
- Member biogears::SEEnvironment::ProcessChange (const SEEnvironmentChange &action)
- Unable to read Configuration Action file
- Member biogears::SEEnvironmentActionCollection::ProcessAction (const CDM::EnvironmentActionData &action)
- Unsupported Action
- Member biogears::SEInhalerActionCollection::ProcessAction (const CDM::InhalerActionData &action)
- Unsupported Action
- Member biogears::SEPatientActionCollection::ProcessAction (const CDM::PatientActionData &action)
Unknown ChestCompression type
Unsupported Action
- Member biogears::Serializer::Initialize (Logger *logger)
Unable to recognize schema grammar
Unable to load
- Member biogears::Serializer::ReadFile (const std::string &xmlFile, Logger *logger)
Serializer was not able to initialize
Error reading xml file
Unsupported root tag
- Member biogears::SESubstanceCompound::Load (const CDM::SubstanceCompoundData &in, const SESubstanceManager &subMgr)
- Could not load find substance compound component for specified substance
- Member biogears::SESubstanceManager::ReadSubstanceFile (const std::string &xmlFile)
- Substance file could not be read in